HP StorageWorks 2/16 - SAN Switch Manual page 110

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
DIAG-TBRAM_WTEST
Message
<timestamp>
CRITICAL DIAG-TBRAM_WTEST, 1, <test name>, pass <number>,
Pt<port info> Failed TurboRAM write test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
wpat=0x<write pattern>
Err# <error code>
Probable Cause
The ASIC internal registers failed on a write operation. This usually indicates an ASIC failure.
This message is generated by the turboramtest command. The error code value is for
internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TIMEOUT
Message
<timestamp>
CRITICAL DIAG-TIMEOUT, 1, <test name>, pass <number>,
Pt<port info> Receive Timeout,
Err# <error code>
Probable Cause
For portloopbacktest and crossporttest:
For centralmemorytest:
This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious
problems in the motherboard or ASIC. The error code value is for internal use only.
110
Port failed to receive frame within timeout period.
Port failed to detect an interrupt within the timeout period.
Fabric OS 3.x Document Addendum