HP StorageWorks 2/16 - SAN Switch Manual page 124

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
SEC-SECVIOL_DCC
Message
<timestamp>
INFO SEC-SECVIOL_DCC, 4, Security violation: Unauthorized device <device
node name> tries to flogin to port <port number> of switch <port node
name>.
Probable Cause
A DCC security violation was reported. The specified device attempted to perform a FLOGI
operation to an unauthorized port. The DCC policy correlates specific devices to specific port
locations. If the device changes connected port, the device is not allowed to perform FLOGI.
Recommended Action
Check the DCC policy and verify that the specified device is allowed in the fabric and is
included in the DCC policy. If the specified device is not included in the policy, add it to the
policy. If the device is not allowed, this is a valid violation message and an unauthorized entity
is trying to gain access to your fabric; take appropriate action as defined by your enterprise
security policy.
Severity
INFO
SEC-SECVIOL_LOGIN
Message
<timestamp>
INFO SEC-SECVIOL_LOGIN, 4, Security violation: Login failure attempt via
<connection method>.
Probable Cause
A login security violation was reported. An incorrect password was used while trying to log in
through a console, telnet, HTTP, or API connection; the login failed.
Recommended Action
Use the correct password.
Severity
INFO
124
Peer IP: <IP address>
Fabric OS 3.x Document Addendum

Advertisement

Table of Contents
loading

Table of Contents