HP StorageWorks 2/16 - SAN Switch Manual page 83

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

DIAG-CAMSTAT
Message
<timestamp>
CRITICAL DIAG-CAMSTAT, 1, <test name>, pass <number>,
Pt<port information> Failed ALI: <idx>, ALPA: 0x<ALPA number> counter:
<cnt>
Err# <error code>
Probable Cause
The ASIC improperly counted the number of frames with CRC errors. This usually indicates
an ASIC failure. This message is generated by the statisticstest command. The
error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CLEAR_ERR
Message
<timestamp>
INFO DIAG-CLEAR_ERR, 3, Pt<port information> Diagnostics Error Cleared
Err# <error code>
Probable Cause
The port diag error flag (OK or BAD) is cleared. The error code value is for internal use
only.
Recommended Action
No action is required.
Severity
INFO
Fabric OS 3.x Document Addendum
Diagnostic and system error messages reference guide
83

Advertisement

Table of Contents
loading

Table of Contents