Diagnostic and system error messages reference guide
This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious
problems in the motherboard or ASIC. This message is generated by the camtest command.
The error code value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-CAMSID
Message
<timestamp>
CRITICAL DIAG-CAMSID, 1, <test name>, pass <number>,
Pt<port information> Failed SID [No] translation test,
SID received is 0x<Actual SID>, SID transmitted 0x<expected SID>,
Err# <error code>
Probable Cause
The ASIC failed the SID NO translation test. This usually indicates an ASIC failure. This
message is generated by the camtest command. The error code value is for internal use
only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
82
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Fabric OS 3.x Document Addendum