Example
To configure:
switch:admin> configure
System services (yes, y, no, n): [no] y
(continued on next page)
Fabric OS 3.x Document Addendum
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [1]
BB credit: (1..27) [16]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
SYNC IO mode: (0..1) [0]
VC Encoded Address Mode: (0..1) [0]
Switch PID Format : (0..2) [1]
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
Virtual Channel parameters (yes, y, no, n): [no] y
VC Priority 2: (2..3) [2]
VC Priority 3: (2..3) [2]
VC Priority 4: (2..3) [2]
VC Priority 5: (2..3) [2]
VC Priority 6: (2..3) [3]
VC Priority 7: (2..3) [3]
Zoning Operation parameters (yes, y, no, n): [no] y
Disable NodeName Zone Checking: (0..1) [0]
RSCN Transmission Mode (yes, y, no, n): [no] y
End-device RSCN Transmission Mode
(0 = RSCN with single PID, 1 = RSCN with multiple PIDs, 2 = Fabric RSCN): (0..2) [1]
Domain RSCN To End-device for switch IP address or name change
(0 = disabled, 1 = enabled): (0..1) [0]
Arbitrated Loop parameters (yes, y, no, n): [no] y
Send FAN frames?: (0..1) [1]
Always Send RSCN?: (0..1) [0]
Enable CLOSE on OPEN received?: (0..4) [4]
Do Not Allow AL_PA 0x00?: (0..1) [0]
Initialize All Looplets?: (0..1) [0]
rstatd (on, off): [off]
rusersd (on, off): [off]
rapid (on, off): [on]
thad (on, off): [on]
Disable RLS probing (on, off): [on]