DIAG-POST_SKIPPED
Message
<timestamp>
WARNING DIAG-POST_SKIPPED, 4, Skipped POST tests: assuming all ports are
healthy,
Err# <error code>
Probable Cause
The POST was not executed on the last boot. The error code value is for internal use only.
Recommended Action
No action is required.
Severity
WARNING
DIAG-REGERR
Message
<timestamp>
CRITICAL DIAG-REGERR, 1, <test name>,
Pt<port info> "<register name>" is <actual value> sb <expected> er <err
value>,
offs <offset value> phy <physical address> msk <mask value>,
Err# <error code>
Probable Cause
The data read from an ASIC register or ASIC SRAM did not match data previously written
into the same location. This usually indicates an ASIC failure. This message is generated by
the portregtest or the sramretentiontest command. The error code value is
for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL