HP StorageWorks 2/16 - SAN Switch Manual page 93

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

DIAG-ERRSTAT (DISCC3)
Message
<timestamp>
CRITICAL DIAG-ERRSTAT (DISCC3), 1, <test name>, pass <number>,
Pt<port information> DiscC3 Error Counter is <number> sb 0,
Err# <error code>
Probable Cause
The Port Error Statistics counter is nonzero, which means that a Discarded Class 3
frames error was detected when receiving frames. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the portloopbacktest or spinsilk command. The error
code value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-ERRSTAT (ENCIN)
Message
<timestamp>
CRITICAL DIAG-ERRSTAT (ENCIN), 1, <test name>, pass <number>,
Pt<port information> Enc_in Error Counter is <number> sb 0,
Err# <error code>
Probable Cause
The Port Error Statistics counter is nonzero, which means that an Encoding error,
inside frame error was detected when receiving frames. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or
ASIC. This message is generated by the portloopbacktest or spinsilk command.
The error code value is for internal use only.
Fabric OS 3.x Document Addendum
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Diagnostic and system error messages reference guide
93

Advertisement

Table of Contents
loading

Table of Contents