Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TBRAM_INC_RWTEST
Message
<timestamp>
CRITICAL DIAG-TBRAM_INC_RWTEST, 1, <test name>, pass <number>,
Pt<port info> Failed TurboRAM inc r/w test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
rpt=0x<actual pattern> wpt=0x<expected pattern> msk=0x<mask value>
Err# <error code>
Probable Cause
The ASIC internal registers failed the read-modify-write operation. This usually indicates an
ASIC failure. This message is generated by the turboramtest command. The error
code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
Fabric OS 3.x Document Addendum