HP StorageWorks 2/16 - SAN Switch Manual page 89

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

DIAG-CMNOBUF
Message
<timestamp>
CRITICAL DIAG-CMNOBUF, 1, <test name>, pass <number>,
Pt<port information> No More Buffers,
Err# <error code>
Probable Cause
The port could not get any buffers. This usually indicates an ASIC failure. This message is
generated by the centralmemorytest command. The error code value is for internal
use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-DATA
Message
<timestamp>
CRITICAL DIAG-DATA, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: RX Data is 0x<actual value>
sb 0x<expected value> er 0x%<err value>,
Err# <error code>
Probable Cause
The payload received by a port did not match the payload transmitted. This can be caused by a
faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard
or ASIC. This message is generated by the crossporttest or portloopbacktest
command. The error code value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Fabric OS 3.x Document Addendum
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Diagnostic and system error messages reference guide
89

Advertisement

Table of Contents
loading

Table of Contents