Chapter 1
Enhanced Array Spanning
The HP NetRAID-1M and 2M adapters allow up to eight arrays to be spanned
together as one logical drive, although all the disks in the logical drive must be
connected to the same adapter. The maximum number of disks connected to one
adapter depends on the number of channels (one or two) and whether you are
using the internal or external SCSI connectors.
Maximum Number of Disk Drives Connected to the
HP NetRAID-1M or 2M Adapter
Model
Using Internal
1M
2M
* External storage with HP Rack Storage/12 supports a maximum of 12 Ultra3 SCSI disk
drives.
Support for Clustering
The HP NetRAID-2M adapter can be used as a shared storage controller in
HP Netserver cluster configurations. HP Netserver clusters provide reliable,
increased-availability solutions for applications where unplanned downtime is
unacceptable.
Either the HP NetRAID-1M or the HP NetRAID-2M adapter can be used as a
local storage controller.
For complete information on clustering, visit the HP Netserver Clustering
Solutions web site at:
http://netserver.hp.com/netserver//

Physical Disk Roaming and Data Migration

HP NetRAID-1M and 2M adapters allow physical disk roaming, in which the
adapter keeps track of disk modules if they are moved to different slots in the
hot-swap cages, as long as the slots are all controlled by the same adapter.
With the exception of the NetRAID-4M, all disk modules on older adapters can
be moved to HP NetRAID-1M and 2M adapters, without losing data readability.
6
Using External
Connectors
6 or fewer
12 or fewer
Introduction
Connectors*
12 or fewer
24 or fewer