To Check Battery Status With Hp Netraid Config; Warnings That Battery Needs Replacement; Changing The Battery Backup Unit; Connecting The Battery Backup Unit - HP P3410A - NetRAID 1M RAID Controller Installation And Configuration Manual

Hp netraid 1m/2m installation & configuration
Hide thumbs Also See for P3410A - NetRAID 1M RAID Controller:
Table of Contents

Advertisement

Chapter 11
2. Choose Objects from the Tools Management menu.
3. Choose Battery Backup to view the battery status.

To Check Battery Status with HP NetRAID Config

1. Start HP NetRAID Config.
2. Choose Objects from the Management menu.
3. Choose Battery Backup to view the battery status.

Warnings That Battery Needs Replacement

Power-up diagnostics include a battery life check. An on-screen message
alerts you if the battery life is low.
HP NetRAID sends an SNMP error message that alerts you of the
condition.

Changing the Battery Backup Unit

Do not attempt to install a new Battery Backup Unit. If the battery needs to be
changed, call an HP Service Representative.

Connecting the Battery Backup Unit

The HP NetRAID-2M adapter is shipped with the Battery Backup Unit installed
and charged, but disconnected. Follow the directions below to connect the Battery
Backup Unit.
CAUTION
When the Battery Backup Unit is connected:
The Battery Backup Unit is a battery pack already installed on the
HP NetRAID-2M adapter. To connect the battery pack, plug the connector
128
HP NetRAID-2M Battery Backup Unit
Do not place the HP NetRAID-2M adapter on a
conductive surface.
When installing the adapter, do not allow the adapter or
its Battery Backup Unit to touch any part of the
HP Netserver. Doing so could short the battery, and it may
damage other components. You may place the adapter on
an antistatic mat.