HP P3410A - NetRAID 1M RAID Controller Installation And Configuration Manual page 149

Hp netraid 1m/2m installation & configuration
Hide thumbs Also See for P3410A - NetRAID 1M RAID Controller:
Table of Contents

Advertisement

Chapter 14
Drives not found at correct positions. Drive Roaming done.
Problem: The physical drives connected to one channel were moved to another
channel on the same adapter and the firmware was able to automatically resolve
and update the configuration.
Solution: This is just a warning message, and there is nothing to be done.
Adapter(s) Swap detected for Cluster/NonCluster mismatch
Problem: Drives connected to a channel on one adapter were moved to another
channel on different adapter and the firmware may or may not be able to resolve
and update the configuration.
Solution: This is treated as a NVRAM mismatch error and the solution is same
as when the following error message is displayed (described above):
Configuration of NVRAM and drives mismatch for Host Adapter – x (Normal
Mismatch)
Run View/Add/Delete Configuration option of Configuration Utility.
Press any key to enter the Configuration Utility.
Error: Following SCSI Disk not found and No Empty Slot Available for mapping it
Problem: The physical disk roaming feature failed to find the physical drive with
the listed SCSI ID, and no slot is available in which to map the physical drive.
The controller cannot resolve the physical drives into a current configuration.
Suggested solution: Reconfigure the array because the adapter cannot resolve the
physical drives into the current configuration.
Following SCSI ID's have the same data <v.z>
Channel-x:a.b.c
Problem: The physical disk roaming feature found the same data on two or more
physical drives on channel (x) with the listed SCSI IDs (a, b, c, and so on). The
adapter cannot determine which drive with duplicate information to use.
Suggested solution: Remove the drive or drives that should not be used.
Troubleshooting
141

Advertisement

Table of Contents
loading

Table of Contents