Chapter 8

Backward Migration

Drives that have been configured with the HP NetRAID-1M or 2M adapters cannot be
migrated to the previous generation of adapters.
Table 8-1 describes the drive migration options for the various combinations of adapters.
Table 8-1. Migration Combinations Permitted
Disks Originally Configured As:
Legacy RAID Disks—NetRAID,
NetRAID-1, NetRAID-3Si,
NetRAID-1Si, integrated HP
NetRAID (LH 3/LH 4), and
integrated HP NetRAID
(LH 3000/LH 6000/LT 6000r)
NetRAID-1M disks
NetRAID-2M disks
NetRAID-4M disks
Upgrading to an HP NetRAID-1M or HP NetRAID-2M Adapter
Adapter Receiving Previously Configured
Disks
Legacy RAID
NetRAID-1M
Adapters
NetRAID-2M
Adapters
Yes
Yes
No
Yes
No
No
NetRAID-4M
Adapter
No
No
Yes
105