Chapter 14
Insufficient Memory
Problem: There is insufficient memory on the adapter for the current
configuration.
Suggested solution: Check the adapter to be sure that the memory is properly
installed.
Following SCSI ID's are not Responding
Channel-x:a.b.c
Problem: On the channel listed (x), the physical drives with the SCSI IDs listed
(a, b, c, and so on) are not responding.
Suggested solution: Verify that the physical drives are connected and powered
on.

Other BIOS Error Messages

Warning: Battery voltage Low
Problem: The voltage of the battery backing the cache memory is low.
Suggested solution: Fast charge the battery. This occurs automatically when the
system is on.
Battery life Low
Problem: The battery backing the cache memory is approaching its predicted end
of life.
Suggested solution: Call an HP Service Representative to replace the battery
backup module.
Battery temperature out of range
Problem: The temperature of the battery backing the cache memory is too low or
too high.
Suggested solution:
If the battery is too cold, allow it to warm up first. The battery will not fast
charge if it is too cold.
If the battery is too hot, check the system for overheating or fan failure.
The battery will not fast charge if it is too hot.