13 Alarm Control and Audible
Warnings
HP NetRAID-1M and 2M adapters have onboard tone generators that indicate
events and errors.
NOTE
Table 13-1. Audible Warnings
Tone Pattern
Three seconds on and
one second off
One second on and
one second off
One second on and
three seconds off
NOTE
To silence a sounding alarm (or to disable or enable the alarm), you must use the
Alarm Control selection in one of the HP NetRAID management utilities. To
reach the Alarm Control setting do the following:
In HP NetRAID Assistant, select the Adapter menu, then Alarm
Control.
In HP NetRAID Config, select Objects, then Adapter, then Alarm
Control.
The integrated HP NetRAID controller does not have alarm
control or audible warnings.
Meaning
A logical drive is offline.
A logical drive is running
in degraded mode.
An automatically initiated
rebuild has been
completed.
RAID 3 and 30 configurations will only be present if you have
migrated from an older controller. You cannot configure new
RAID 3 or 30 configurations on an HP NetRAID-1M or 3M
adapter.
Examples
One or more drives in a RAID 0
configuration failed.
Two or more drives in a RAID 1, 3,
5, 10, 30, or 50 configuration
failed.
One drive in a RAID 3, 5, 30, or 50
configuration failed.
While you were away from the
system, a disk drive in a RAID 1, 3,
5, 10, 30, or 50 configuration failed
and was rebuilt.