Introduction
This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12FC
and Microsoft Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless
and provide extended availability. The specific configuration certified and supported by both Hewlett-
Packard and Microsoft is defined, as are other guidelines to assist you in configuring your clustered
NetServers. This guide is prescriptive; it describes the configurations supported by HP. Any deviance to
these configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Racked Cluster
Cluster
Type of SPUs
Number of nodes
Shared Storage
LANs:
1
For more information about configuring a SPOFless cluster, refer to the HP white paper, High Availability
MSCS Cluster Solution on the HP NetServers, HA Planning website.
HP NetServer LT 6000r
with
HP Rack Storage/12FC
Windows 2000 Advanced Server
Cluster Configuration Guide
29 January 2001
(see
Versions
at the end of this document)
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
HP NetServer LT 6000r
Each node must be the same model SPU, but may have different sizes of
main memory and cache, and different CPU clock speeds.
2
HP Rack Storage/12FC with 2 FCArray Cards, HP disks, and using an HP
D8602A or D8602B HBA in each server. See
1
1
Shared Storage
below.
)

Advertisement

loading

Summary of Contents for HP D7171A - NetServer - LPr

  • Page 1 HP NetServer LT 6000r with HP Rack Storage/12FC Windows 2000 Advanced Server Cluster Configuration Guide 29 January 2001 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12FC and Microsoft Cluster Server.
  • Page 2 Client LAN Any NIC that is HP and Microsoft approved. See Client LAN below. For a SPOFless cluster, two D5013B NICs configured with AFT is recommended. Intra-cluster Embedded NIC with crossover cable, or, configure as a VLAN through an (Heartbeat) LAN Ethernet switch.
  • Page 3 Host Bus Adapter Model HP Fibre Channel Host Bus Adapter - HP D8602A or D8602B No. of controllers Driver D8602A - Hhba5100.sys 2.06 D8602B - Afcw2k.sys 3.0.3245.1 RAID level 0,1, 3, 5, 10 For SPOFless configurations a fault tolerant RAID type, e.g. RAID 5, is recommended for all shared storage.
  • Page 4: Shared Storage Cabling

    Model HP Rack Storage/12 – D5989B plus two D6025B or two D6025C SCSI cards for each cabinet Status SCSI ID 5 (fixed) Disk SCSI IDs 0 – 3, 8 – 15 (fixed) Disk drives: Same as HP Rack Storage/12FC Cables Any HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A...
  • Page 5 HP Microsoft Cluster (SPOF) using HP Rack Storage/12FC and Rack Storage/12 and 6 Port Fibre Channel Hub...
  • Page 6 Power Cabling to Separate Power Circuits (For SPOFless with 2 hubs, connect second hub to PDU that first hub is not attached to)
  • Page 7 HP SPOFless Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 and two 6 Port Fibre Channel Hubs...
  • Page 8 HP SPOFless Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 with Direct Connections...
  • Page 9 Versions 29 January 2001 Added D8602B and driver. 7 December 2000 Corrected 2 hub spofless diagram 29 November 2000 Changed power diagram —all cords to same PDU. 5 October 2000 Added SPOFless configuration notes and diagrams. 23 May 2000 Initial release.