Running Online Diagnostic Tests

This example shows how to enable the generation of a syslog message when any health-monitoring test
fails:
Router(config)# diagnostic monitor syslog
Router(config)#
Running Online Diagnostic Tests
After you configure online diagnostics, you can start or stop diagnostic tests or display the test results.
You can also see which tests are configured for each module and what diagnostic tests have already run.
These sections describe how to run online diagnostic tests after they have been configured:

Starting and Stopping Online Diagnostic Tests

After you configure diagnostic tests to run on the switch or individual modules, you can use the start
and stop to begin or end a diagnostic test.
To start or stop an online diagnostic command, perform one of these tasks:
Command
diagnostic start {module num} test {test_id |
test_id_range | minimal | complete | basic | per-port
| non-disruptive
| all} [port {num | port#_range | all}]
diagnostic stop {module num}
This example shows how to start a diagnostic test on a specific module:
Router# diagnostic start module 1 test 5
Module 1:Running test(s) 5 may disrupt normal system operation
Do you want to run disruptive tests? [no]yes
00:48:14:Running OnDemand Diagnostics [Iteration #1] ...
00:48:14:%DIAG-SP-6-TEST_RUNNING:Module 1:Running TestNewLearn{ID=5} ...
00:48:14:%DIAG-SP-6-TEST_OK:Module 1:TestNewLearn{ID=5} has completed successfully
00:48:14:Running OnDemand Diagnostics [Iteration #2] ...
00:48:14:%DIAG-SP-6-TEST_RUNNING:Module 1:Running TestNewLearn{ID=5} ...
00:48:14:%DIAG-SP-6-TEST_OK:Module 1:TestNewLearn{ID=5} has completed successfully
Router#
This example shows how to stop a diagnostic test on a specific module:
Router# diagnostic stop module 3
Router#

Displaying Online Diagnostic Tests and Test Results

You can display the online diagnostic tests that are configured for specific modules and check the results
of the tests using the show commands.
Catalyst Supervisor Engine 32 PISA Cisco IOS Software Configuration Guide, Release 12.2ZY
51-6
Starting and Stopping Online Diagnostic Tests, page 51-6
Displaying Online Diagnostic Tests and Test Results, page 51-6
Chapter 51
Purpose
Starts a diagnostic test on a specific module and port or range
of ports.
Stops a diagnostic test on a specific module.
Configuring Online Diagnostics
OL-11439-03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst supervisor engine 32 pisa

Table of Contents