Configuring The Etherchannel Min-Links Feature - Cisco WS-SUP32-GE-3B - Supervisor Engine 32 Software Configuration Manual

Software configuration guide
Hide thumbs Also See for WS-SUP32-GE-3B - Supervisor Engine 32:
Table of Contents

Advertisement

Chapter 10
Configuring EtherChannels
This example shows how to configure EtherChannel to use source and destination IP addresses:
Router# configure terminal
Router(config)# port-channel load-balance src-dst-ip
Router(config)# end
Router(config)#
This example shows how to verify the configuration:
Router# show etherchannel load-balance
Source XOR Destination IP address
Router#

Configuring the EtherChannel Min-Links Feature

The EtherChannel Min-Links feature is supported on
configure the minimum number of member ports that must be in the link-up state and bundled in the
EtherChannel for the port channel interface to transition to the link-up state. You can use the
EtherChannel Min-Links feature to prevent low-bandwidth LACP EtherChannels from becoming active.
This feature also causes LACP EtherChannels to become inactive if they have too few active member
ports to supply your required minimum bandwidth.
To configure the EtherChannel Min-Links feature, perform this task:
Command
Step 1
Router(config)# interface port-channel number
Step 2
Router(config-if)# port-channel min-links number
Router(config-if)# no port-channel min-links
Step 3
Router(config-if)# end
Step 4
Router# show running-config interface type
slot/port
Router# show interfaces type
etherchannel
Note
Although the EtherChannel Min-Links feature works correctly when configured only on one end of an
EtherChannel, for best results, configure the same number of minimum links on both ends of the
EtherChannel.
OL-11439-03
src-dst-mac—Source and destination MAC addresses
src-dst-port—Source and destination Layer 4 port
src-ip—Source IP addresses
src-mac—Source MAC addresses
src-port—Source Layer 4 port
1
slot/port
Catalyst Supervisor Engine 32 PISA Cisco IOS Software Configuration Guide, Release 12.2ZY
LACP
Purpose
Selects an LACP port channel interface.
Configures the minimum number of member ports that
must be in the link-up state and bundled in the
EtherChannel for the port channel interface to transition
to the link-up state.
Reverts to the default number of active member ports
(one).
Exits configuration mode.
1
Verifies the configuration.
Configuring EtherChannels
EtherChannels. This feature allows you to
10-11