Chapter 50
Power Management and Environmental Monitoring
Router# show environment cooling
fan-tray 1:
fan-tray 1 fan-fail: failed
fan-tray 2:
fan 2 type: FAN-MOD-9
fan-tray 2 fan-fail: OK
chassis cooling capacity: 690 cfm
ambient temperature: 55C
chassis per slot cooling capacity: 75 cfm
module 1 cooling requirement: 70 cfm
module 2 cooling requirement: 70 cfm
module 5 cooling requirement: 30 cfm
module 6 cooling requirement: 70 cfm
module 8 cooling requirement: 70 cfm
module 9 cooling requirement: 30 cfm
Router# show environment status
backplane:
operating clock count: 2
operating VTT count: 3
fan-tray 1:
fan-tray 1 type: WS-9SLOT-FAN
fan-tray 1 fan-fail: OK
VTT 1:
VTT 1 OK: OK
VTT 1 outlet temperature: 33C
VTT 2:
VTT 2 OK: OK
VTT 2 outlet temperature: 35C
VTT 3:
VTT 3 OK: OK
VTT 3 outlet temperature: 33C
clock 1:
clock 1 OK: OK, clock 1 clock-inuse: in-use
clock 2:
clock 2 OK: OK, clock 2 clock-inuse: not-in-use
power-supply 1:
power-supply 1 fan-fail: OK
power-supply 1 power-output-fail: OK
module 1:
module 1 power-output-fail: OK
module 1 outlet temperature: 30C
module 1 device-2 temperature: 35C
RP 1 outlet temperature: 35C
RP 1 inlet temperature: 36C
EARL 1 outlet temperature: 33C
EARL 1 inlet temperature: 31C
module 2:
module 2 power-output-fail: OK
module 2 outlet temperature: 31C
module 2 inlet temperature: 29C
module 3:
module 3 power-output-fail: OK
module 3 outlet temperature: 36C
module 3 inlet temperature: 29C
module 4:
module 4 power-output-fail: OK
module 4 outlet temperature: 32C
module 4 inlet temperature: 32C
module 5:
module 5 power-output-fail: OK
module 5 outlet temperature: 39C
module 5 inlet temperature: 34C
OL-11439-03
Catalyst Supervisor Engine 32 PISA Cisco IOS Software Configuration Guide, Release 12.2ZY
Understanding How Environmental Monitoring Works
["40C (user-specified)" if temp-controlled]
50-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst supervisor engine 32 pisa

Table of Contents