TX Matrix Hardware Guide
Related
Documentation
TX Matrix Three-Input 240-A Power Supply LEDs
46
Table 16: Fault Tolerance
Redundancy
Nonredundant power supply
Redundant power supplies
TX Matrix Power System Description on page 41
TX Matrix Three-Input 240-A Power Supply LEDs on page 46
Installing a TX Matrix Three-Input 240-A DC Power Supply on page 279
Maintaining the Power Supplies on page 203
Troubleshooting the TX Matrix Power System on page 213
TX Matrix DC Power Supply Specifications on page 338
LEDs on each power supply faceplate (see Figure 24 on page 46) indicate the status of
the power supply. In addition, a power supply failure triggers the red alarm LED on the
craft interface. Table 17 on page 46 describes the functions of the power supply LEDs.
Figure 24: Three-Input 240-A DC Power Supply LEDs
Table 17 on page 46 describes the three-input 240-A DC power supply LEDs.
Table 17: Three-Input 240-A DC Power Supply LEDs
LED
Color
—One per
Green
CB ON
input
Fault Tolerance When One Input Fails or is Disconnected
If this input fails, the router shuts down.
NOTE: We recommend that you install redundant power
supplies.
If an input on one power supply fails, the other power supply
assumes the electrical load for all inputs. If one input on the other
power supply is not functional, the router shuts down.
State
Description
On steadily
Circuit breaker is on.
Off
Circuit breaker is not turned on, or
host subsystem has detected a
failure and has turned the circuit
breaker off.
Copyright © 2010, Juniper Networks, Inc.