Catalyst 6506 Switch - Cisco 6503 - Catalyst Firewall Security Sys Installation Manual

Installation guide
Hide thumbs Also See for 6503 - Catalyst Firewall Security Sys:
Table of Contents

Advertisement

Chapter 1
Product Overview
Table 1-7
Table 1-7
Catalyst 6506 Switch Features
Feature
Chassis
Supervisor engines
OL-5781-08
lists the features of the Catalyst 6506 switch chassis.
Descriptions
Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom).
Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor
Engine 32 PISA, Supervisor Engine 720, and Supervisor
Engine 720-10GE.
Note
Refer to your software release notes for the minimum software
release versions required to support the supervisor engines.
Supervisor Engine 2 must be installed in slot 1 or slot 2.
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
Engine 720, and Supervisor Engine 720-10GE must be installed in
slot 5 or slot 6.
Note
Slots not occupied by supervisor engines can be used for modules.
Check your software release notes for any restrictions on the type of
module that can be installed.
Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor
Engine 720, and Supervisor Engine 720-10GE all require the
high-speed fan tray (WS-C6K-6SLOT-FAN2) be installed in the chassis.
You must also install a 2500 W or higher capacity power supply in the
chassis to power the high-speed fan tray.
The 2500 W power supply, when supporting the high-speed fan tray,
Note
can be powered from either 120 VAC or 220 VAC.
Supervisor Engine 720 and Supervisor Engine 720-10GE have a built-in
switching fabric. Switch Fabric Modules (WS-C6500-SFM and
WS-X6500-SFM2) are not supported by Supervisor Engine 720 and
Supervisor Engine 720-10GE.
Supervisor Engine 32 and Supervisor Engine 32 PISA do not support
the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2).
The uplink ports are fully functional on the redundant supervisor engine
in standby mode.
In systems with redundant supervisor engines, both supervisor
Note
engines must be the same model and have the same daughter card
configurations. Each supervisor engine must have the resources to
run the switch on its own, which means that all supervisor engine
resources are duplicated. Identical supervisor engine memory
configurations are recommended, but are not required as long as the
supervisor engine with the smaller memory configuration is
sufficient to run the configured features of the switch. Additionally,
each supervisor engine must have its own flash device and console
port connections.
Catalyst 6500 Series Switches Installation Guide

Catalyst 6506 Switch

1-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6500 series

Table of Contents