Catalyst 6504-E Switch
Table 1-6
Table 1-6
Catalyst 6504-E Switch Specifications
Item
Environmental
Temperature, operating
Temperature, nonoperating
and storage
Thermal transition
Humidity (RH), ambient
(noncondensing) operating
Humidity (RH), ambient
(noncondensing)
nonoperating and storage
Altitude, operating
Shock and vibration
Catalyst 6500 Series Switches Installation Guide
1-16
lists the environmental and physical specifications of the Catalyst 6504-E switch chassis.
Specification
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 131°F (0° to 55°C)
The Catalyst 6500 series switches are equipped with internal air
Note
temperature sensors that are triggered at 104°F (40°C) generating a
minor alarm and at 131°F (55°C) generating a major alarm.
Chassis unpackaged: –4° to 149°F (–20° to 65°C)
Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
0.5°C per minute (hot to cold)
0.33°C per minute (cold to hot)
5% to 90%
5% to 95%
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for: –200 to 10,000 ft (–60 to 3000 m)
This switch complies with Network Equipment Building Systems (NEBS)
(Zone 4 per GR-63-Core) in the following areas:
Earthquake environment and criteria
Office vibration and criteria
Transportation vibration and criteria
Shock
Operational—5 G 30 ms, half-sine (IEC 68-2-27)
Nonoperational—20 G, 7.5 ms, trapezoidal
Vibration
Operational—3 Hz to 500 Hz.
Power Spectral Density (PSD)—0.0005 G
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).