Appendix A
Power Supply Specifications
Table A-12
LED
INPUT OK
FAN OK
OUTPUT FAIL
1300 W Power Supply AC Power Cords
Table A-13
power supply. The table includes references to power cord illustrations.
All 1300 W power supply power cords are 14 feet (4.3 meters) in length.
Note
Note
All 1300 W power supply power cords have an IEC60320/C19 appliance connector at one end.
OL-5781-08
1300 W AC-Input and DC-Input Power Supply LEDs
Meaning
AC-input power supplies:
•
Green—Source AC voltage is OK. (Input voltage is 85 VAC or
greater.)
Off—Source AC voltage falls below 70 VAC, is not present, or the
•
power supply turned off.
DC-input power supplies:
•
Green—Source DC voltage is OK. (Input voltage is –40.5 VDC or
greater.)
Off—Source DC voltage falls below –33 VDC, is not present, or the
•
power supply is turned off.
Green—Power supply fan is operating properly.
•
•
Off—Power supply fan failure is detected.
Red—Problem with one or more of the DC-output voltages of the
•
power supply is detected.
•
Off—DC-output voltages within acceptable margins.
Note
lists the specifications for the AC power cords that are available for the 1300 W AC-input
1300 W AC-Input and DC-Input Power Supplies
For proper operation of the OUTPUT FAIL LED, systems with
single power supplies must be configured with a minimum of
one fan tray and one supervisor engine. Systems with dual power
supplies must have a minimum configuration of one fan tray, one
supervisor engine, and one additional module. Failure to meet
these minimum configuration requirements can cause a false
power supply output fail signal.
Catalyst 6500 Series Switches Installation Guide
A-17