Verifying Switch Chassis Installation; Online Diagnostics - Cisco 6503 - Catalyst Firewall Security Sys Installation Manual

Installation guide
Hide thumbs Also See for 6503 - Catalyst Firewall Security Sys:
Table of Contents

Advertisement

Verifying Switch Chassis Installation

Verifying Switch Chassis Installation
To verify the switch chassis installation, follow these steps:
Step 1
Verify that the ejector levers of each module are fully closed (parallel to the faceplate) to ensure that the
supervisor engine and all switching modules are fully seated in the backplane connectors.
Check the captive installation screws of each module, the power supply, and the fan assembly. Tighten
Step 2
any loose captive installation screws.
Verify that all empty module slots have blank faceplates installed and that the screws holding the plates
Step 3
in place are tight. The blank faceplates optimize the air flow through the chassis and contain
electromagnetic interference.
Blank faceplates and cover panels serve three important functions: they prevent exposure to
Warning
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
Turn on the power supply switches to power up the system. During the power-up sequence, the system
Step 4
performs a series of bootup diagnostic tests.
Additional system diagnostic tests are available. These tests allow you to perform a complete sanity
check on the system prior to inserting the system into your network and to monitor the health of the
system while the system is running. Refer to the
information.
Tip

Online Diagnostics

The Catalyst 6500 series systems running Cisco IOS have many levels of online diagnostic capabilities.
The online diagnostics are divided into four categories:
Catalyst 6500 Series Switches Installation Guide
3-84
When prestaging systems in a nonproduction environment, we recommend that you run all
diagnostic tests, including the disruptive tests, to prescreen the systems for any failures.
Bootup—Bootup diagnostics automatically run during bootup, module OIR, or switchover to a
backup supervisor engine.
Background health—Monitoring diagnostic tests are continuously run by the system to monitor
system health.
"Online Diagnostics" section on page 3-84
Chapter 3
Installing the Switch
for further
OL-5781-08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6500 series

Table of Contents