C H A P T E R 4 Removal And Replacement Procedures; Removing And Installing The 950 W And 1400 W Ac-Input Power Supplies - Cisco 6503 - Catalyst Firewall Security Sys Installation Manual

Installation guide
Hide thumbs Also See for 6503 - Catalyst Firewall Security Sys:
Table of Contents

Advertisement

Chapter 4
Removal and Replacement Procedures
The following power supply restrictions exist for the Catalyst 6500 series chassis:
Note

Removing and Installing the 950 W and 1400 W AC-Input Power Supplies

This section describes how to remove and install the 950 W and 1400 W AC-input power supplies for
the Catalyst 6503 and the Catalyst 6503-E switches. The section is divided into the following topics:
The 950 W and 1400 W AC-input power supplies can be installed in the Catalyst 6503 and the
Note
Catalyst 6503-E switch chassis only.
Required Tools
You might need a flat-blade or number 2 Phillips-head screwdriver to loosen or tighten the captive
installation screws on the power supply.
Removing a 950 W or 1400 W AC-Input Power Supply
Hazardous voltage or energy is present on the backplane when the system is operating. Use
Warning
caution when servicing. Statement 1034
In systems with redundant power supplies, you can replace the faulty supply while the system is
Note
operating.
This procedure covers the removal of the power supply only. For information on removing the power
Note
entry module (PEM), see the
OL-5781-08
The 6000 W and the 8700 W power supplies are limited to 4000 W when they are installed in the
Catalyst 6506, Catalyst 6509, and Catalyst 6509-NEB chassis.
The 8700 W power supply is limited to 4500 W when it is installed in a Catalyst 6509-NEB-A
chassis.
The 8700 W power supply is limited to 6000 W when it is installed in a Catalyst 6513 chassis.
Required Tools, page 4-3
Removing a 950 W or 1400 W AC-Input Power Supply, page 4-3
Installing a 950 W or 1400 W AC-Input Power Supply, page 4-5
"Removing and Installing PEMs" section on page
Removing and Installing the AC-Input Power Supplies
Catalyst 6500 Series Switches Installation Guide
4-75.