Chapter 1
Product Overview
Table 1-11
Catalyst 6509 Switch Features (continued)
Feature
Power supply
OL-5781-08
Description
Supports one or two power supplies. The following power supply
models are supported:
WS-CAC-1000W (1000 W AC-input power supply).
WS-CAC-1300W (1300 W AC-input power supply).
WS-CDC-1300W (1300 W DC-input power supply).
WS-CAC-2500W (2500 W AC-input power supply).
WS-CDC-2500W (2500 W DC-input power supply).
WS-CAC-3000W (3000 W AC-input power supply).
WS-CAC-4000W-US (4000 W AC-input power supply).
WS-CAC-4000W-INT (4000 W AC-input power supply).
PWR-4000-DC (4000 W DC-input power supply).
WS-CAC-6000W (6000 W AC-input power supply).
PWR-6000-DC (6000 W DC-input power supply).
WS-CAC-8700W-E (8700 W AC-input power supply).
Note
The 6000 W AC-input and DC-input power supplies and the 8700 W
AC-input power supply are limited to 4000 W maximum output
when installed in the Catalyst 6509 chassis.
Installed power supplies can be of different wattage ratings. Installed
power supplies can also be both AC-input, both DC-input, or one
AC-input and one DC-input. Power supplies can be configured in either
redundant or combined mode.
All Catalyst 6500 series AC-input power supplies require single-phase
source AC. Source AC can be out of phase between multiple power
supplies or multiple AC-power plugs on the same power supply because
all AC power supply inputs are isolated.
Single power supplies are installed in the left power supply bay. The
second (redundant) power supply is installed in the right power supply
bay.
You must install a 2500 W or higher capacity power supply when using
the Supervisor Engine 32 or the Supervisor Engine 720 and the
high-speed fan tray.
For proper operation of the power supply OUTPUT FAIL LED,
Note
systems with single power supplies must be configured with a
minimum of one fan tray and one supervisor engine. Systems with
dual power supplies must have a minimum configuration of one fan
tray, one supervisor engine, and one additional module. Failure to
meet these minimum configuration requirements can cause a false
power supply output fail signal.
Catalyst 6500 Series Switches Installation Guide
Catalyst 6509 Switch
1-33