Catalyst 6503 Switch
Table 1-2
Table 1-2
Catalyst 6503 Switch Specifications
Item
Environmental
Temperature, operating
Temperature, nonoperating
and storage
Thermal transition
Humidity (RH), ambient
(noncondensing) operating
Altitude, operating
Shock and vibration
Acoustic noise
Catalyst 6500 Series Switches Installation Guide
1-6
lists the environmental and physical specifications of the Catalyst 6503 switch chassis.
Specification
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 131°F (0° to 55°C)
The Catalyst 6500 series switches are equipped with internal air
Note
temperature sensors that are triggered at 40°C (104°F) generating a
minor alarm and at 55°C (131°F) generating a major alarm.
Chassis unpackaged: –4° to 149°F (–20° to 65°C)
Chassis in protective shipping package: –40° to 158°F (–40° to 70°C)
0.5°C per minute (hot to cold)
0.33°C per minute (cold to hot)
Operating: 5% to 90%
Nonoperating and storage: 5% to 95%
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
This switch was complies with Network Equipment Building Systems
(NEBS) (Zone 4 per GR-63-Core) in the following areas:
Earthquake environment and criteria
•
Office vibration and criteria
•
Transportation vibration and criteria
•
Shock
Operational—5 G 30 ms, half-sine (IEC 68-2-27)
•
•
Nonoperational—20 G, 7.5 ms, trapezoidal
Vibration
Operational—3 Hz to 500 Hz,
Power Spectral Density (PSD)—0.0005 G
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
64 to 76 dB. International Organization for Standardization (ISO) 7779:
Bystander position operating to an ambient temperature of 86°F (30°C).
Chapter 1
2
/Hz at 10 Hz and 200 Hz.
Product Overview
OL-5781-08