D19 Plc: Transfer Values To The Plc - HEIDENHAIN ITNC 530 - 6-2010 DIN-ISO PROGRAMMING User Manual

Din/iso programming
Table of Contents

Advertisement

D19 PLC: Transfer values to the PLC

The function D19 transfers up to two numerical values or Q parameters
to the PLC.
Increments and units: 0.1 µm or 0.0001°
Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC
N56 D19 P01 +10 P02 +Q3 *