Single beam transducer to split beam transceiver

This is the termination of the transducer cable from a single frequency, single beam
transducer to the socket on a split beam General Purpose Transceiver Unit (GPT). The
other end of the cable is permanently fixed to the transducer.
If you need to splice the transducer cable, it is very important to use the correct cable,
and to avoid ground loops. We strongly recommend the use of a junction box. We also
recommend that you install the transducer cable in a steel conduit.
For more information, see:
Transducer cable splicing on page 142
Steel conduit on page 142
GPT Transducer plug connection on page 107