Intel
Entry Server Chassis SC5299-E TPS
kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test
specification. The
step load may occur anywhere between the MIN load and MAX load
conditions.
Output
+ 3.3VDC
+ 5VDC
+12VDC (12V1/2/3/4/5)
- 12VDC
+5VSB
2.4.3.1
DC/DC Converter Capacitive Loading
All outputs of the DC/DC converter are stable and meet all requirements with the following
capacitive loading ranges.
+3.3VDC
+5VDC
-12VDC
Note: Refer to the Power Supply specification for the equivalent data on +12V and +5VSB output.
2.4.3.2
DC/DC Converters Closed Loop Stability
Each DC/DC converter is unconditionally stable under all line/load/transient load conditions,
including capacitive load ranges. A minimum of 45 degrees phase margin and –10dB-gain
margin is required.
2.4.3.3
Common Mode Noise
The common mode noise on any output does not exceed 350 mV peak-peak over the frequency
band of 10 Hz to 30 MHz.
Revision 3.1
Table 86. Transient Load Requirements
Max
Step Load Size
5.0A
4.0A
See the Power Supply specification for details.
Not rated
See the the Power Supply specification for details.
Table 87. Capacitive Loading Conditions
Converter Output
MIN
250
400
Intel order number D37594-005
Max Load Slew Rate
0.25 A/ s
0.25 A/ s
Not rated
MAX
6,800
4,700
1
350
Power Sub-system
Test capacitive Load
250 F
400 F
F
Units
F
F
F
71