Table 110. Ac Input Rating; Table 111. Efficiency; Table 112. Ac Line Dropout/Holdup - Intel SC5299BRP Technical Product Specification

Entry server chassis
Table of Contents

Advertisement

Power Sub-system
Parameter
MIN
Voltage (110)
90 V
rms
Voltage (220)
180 V
rms
Frequency
47 Hz
1.
Maximum input current at low input voltage range is measured at 90VAC, at max load.
2.
Maximum input current at high input voltage range is measured at 180VAC, at max load.
3.
This requirement is not used for determining agency input current markings.
2.5.7.4
Efficiency
The following table provides the required minimum efficiency level at various loading conditions.
These efficiency levels are provided at three different load levels: 100%, 50% and 20%.
Efficiency is tested over an AC input voltage range of 115VAC to 220VAC.
Loading
Recommended Efficiency
2.5.7.5
AC Line Dropout/Holdup
Output Wattage
670W
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC
line for any length of time. During an AC dropout, the power supply meets dynamic voltage
regulation requirements. An AC line dropout of any duration does not cause any tripping of
control signals or protection circuits. If the AC dropout lasts longer than the hold up time, the
power recovers and meets all turn on requirements. The power supply meets the AC dropout
requirement over rated AC voltages and frequencies. A dropout of the AC line for any duration
does not cause damage to the power supply.
2.5.7.5.1
AC Line 5VSB Holdup
The 5VSB output voltage stays in regulation under its full load (static or dynamic) during an AC
dropout of 70ms min (=5VSB holdup time) whether the power supply is in the ON or OFF state
(PSON asserted or de-asserted).
90

Table 110. AC Input Rating

Rated
V
MAX
100-127 V
140 V
rms
rms
200-240 V
264 V
rms
rms
50/60
63 Hz

Table 111. Efficiency

100% of Maximum
68%

Table 112. AC Line Dropout/Holdup

Loading
100%
Intel order number D37594-005
®
Intel
Entry Server Chassis SC5299-E TPS
I
MAX
1,3
12 A
2,3
7 A
50% of Maximum
72%
Holdup time
20 ms
Start up VAC
Power Off VAC
85VAC +/-
75VAC +/-
4VAC
5VAC
20% of Maximum
65%