Chassis Power Subsystem
3.1.5

600-W DC Output Specifications

3.1.5.1
Grounding
The output ground of the pins of the power supply provides the return path. The output
connector ground pins is to the safety ground (power supply enclosure).
3.1.5.2
Output Voltage and Currents
The following tables define two power and current ratings for the 600-W power supply. The
combined output power of all outputs shall not exceed the rated output power.
Voltage
+3.3V6
6
+5V
+12V1
+12V2
+12V3
+12V4
-12V
+5VSB
Voltage
+3.3V6
6
+5V
+12V1
+12V2
+12V3
+12V4
-12V
+5VSB
Notes:
(1) Maximum continuous total DC output power should not exceed 600 W.
30

Table 13. Maximum System Load Ratings

Minimum
Continuous
Continuous Load
Load
1.5 A
20 A
5.0 A
24 A
1.5 A
15 A
1.5 A
15 A
1.5 A
16 A
1.5 A
16 A
0 A
0.5 A
0.1 A
2.0 A

Table 14. Light System Load Ratings

Minimum
Continuous Load
Continuous Load
0.5 A
9.0 A
2.0 A
7.0 A
0.5 A
5.0 A
0.5 A
5.0 A
2.0 A
6.0 A
0.5 A
5.0 A
0 A
0.5 A
0.1 A
2.0 A
Intel® Server Chassis SC5300 5U Kit TPS
Maximum
Peak Load
1, 3
18 A
18 A
18 A
18 A
Maximum
Peak Load
7.0 A
7.0 A
2, 4, 5
5