Power Sub-system
2.1.2
Airflow and Temperature
The power supply operates within all specified limits over the T
average air temperature difference ( T
not exceed 20C. All airflow passes through the power supply and not over the exterior surfaces
of the power supply.
Item
T
Operating temperature range.
op
T
Non-operating temperature range.
non-op
Altitude
Maximum operating altitude
The power supply meets UL enclosure requirements for temperature rise limits. All sides of the
power supply, with the exception of the air exhaust side, are classified as "Handle, knobs, grips,
etc. held for short periods of time only".
2.1.3
Output Cable Harness
Listed or recognized component appliance wiring material (AVLV2), CN, rated min 105 C,
300Vdc is used for all output wiring.
10
) from the inlet to the outlet of the power supply does
ps
Table 2. Environmental Requirements
Description
Intel order number D37594-005
®
Intel
Entry Server Chassis SC5299-E TPS
temperature range. The
op
Min
Specification
0
50
-40
70
1500
Units
C
C
m
Revision 3.1