Table 120. Pre-Set Lighter Load - Intel SC5299BRP Technical Product Specification

Entry server chassis
Table of Contents

Advertisement

®
Intel
Entry Server Chassis SC5299-E TPS
+5V
+12V(1, 2, 3, 4)
-12V
+5VSB
2.5.8.8
Closed Loop Stability
The power supply is unconditionally stable under all line/load/transient load conditions, including
capacitive load ranges. A minimum of 45 degrees phase margin and -10dB-gain margin are
required. Closed-loop stability is ensured at the maximum and minimum loads, as applicable.
2.5.8.9
Residual Voltage Immunity in Standby Mode
The power supply is immune to any residual voltage placed on its outputs (typically a leakage
voltage through the system from standby output) up to 500mV. There is neither additional heat
generated, nor stress of any internal components with this voltage applied to any individual
output, and all outputs simultaneously. It also does not trip the protection circuits during turn on.
The residual voltage at the power supply outputs for no load condition does not exceed 100mV
when AC voltage is applied.
2.5.8.10
Common Mode Noise
The common mode noise on any output does not exceed 350mV pk-pk over the frequency band
of 10Hz to 30MHz.
2.5.8.11
Soft Starting
The power supply contains a control circuit that provides monotonic soft start for its outputs
without overstress of the AC line or any power supply components at any specified AC line or
load conditions. There is no requirement for rise time on the 5Vstby but the turn on/off is
monotonic.
2.5.8.12
Pre-set Power-on Requirement
When the power supply turns on, the system loading maybe very light before it comes out of
reset. Under these conditions, the power supply's output voltage regulation may be relaxed to
+/-10% on the 3.3V and 5V rails and +10/-8% on the +12V rails. When the power supply is
subsequently loaded, it must begin to regulate and source current without fault.
Voltage
+3.3V
Revision 3.1
Output
MIN
400
500 each
1
20

Table 120. Pre-set Lighter Load

Minimum Continuous
Load
0 A
Intel order number D37594-005
MAX
4700
11,000
350
350
Maximum Continuous
Load
9.0 A
Power Sub-system
Units
F
F
F
F
Peak Load
97