Power Sub-system
Duration
Sag
Continuous
10%
0 to 1 AC cycle
100%
> 1 AC cycle
>10%
Duration
Surge
Continuous
10%
0 to ½ AC
30%
cycle
2.2.2.3
Susceptibility Requirements
The power supply meets the following electrical immunity requirements when connected to a
cage with an external EMI filter that meets the criteria defined in the SSI document EPS Power
Supply Specification.
Level
A
B
C
2.2.2.3.1
Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-
2:1995 and the level 3 test standard and performance criteria B defined in Annex B of CISPR
24.
28
Table 24. AC Line Sag Transient Performance
Operating AC Voltage
Nominal AC Voltage ranges
Nominal AC Voltage ranges
Nominal AC voltage ranges
Table 25. AC Line Surge Transient Performance
Operating AC Voltage
Nominal AC Voltages
Mid-point of nominal AC
voltages
Table 26. Performance Criteria
The apparatus shall continue to operate as intended. No degradation of
performance.
The apparatus shall continue to operate as intended. No degradationof
performance beyond spec limits.
Temporary loss of function is allowed provided the function is self-recoverable or
can be restored by the operation of the controls.
Intel order number D37594-005
®
Intel
Entry Server Chassis SC5299-E TPS
Line
Frequency
50/60Hz
No loss of function or performance
50/60Hz
No loss of function or performance
50/60Hz
Loss of function acceptable, self
recoverable
Line Frequency
50/60Hz
No loss of function or performance
50/60Hz
No loss of function or performance
Description
Performance Criteria
Performance Criteria
Revision 3.1