Alcatel OS-LS-6224 User Manual page 549

User guide
Hide thumbs Also See for OS-LS-6224:
Table of Contents

Advertisement

Example
The following example displays RMON 1 alarms.
Console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample
The statistic value during the last sampling period. For example, if the sample type
Value
is delta, this value is the difference between the samples at the beginning and end
of the period. If the sample type is absolute, this value is the sampled value at the
end of the period.
Interval
The interval in seconds over which the data is sampled and compared with the rising
and falling thresholds.
Sample Type
The method of sampling the variable and calculating the value compared against
the thresholds. If the value is absolute, the value of the variable is compared
directly with the thresholds at the end of the sampling interval. If the value is delta,
the value of the variable at the last sample is subtracted from the current value, and
the difference compared with the thresholds.
Startup Alarm
The alarm that may be sent when this entry is first set. If the first sample is greater
than or equal to the rising threshold, and startup alarm is equal to rising or rising and
falling, then a single rising alarm is generated. If the first sample is less than or equal
to the falling threshold, and startup alarm is equal falling or rising and falling, then a
single falling alarm is generated.
Rising Threshold
A sampled statistic threshold. When the current sampled value is greater than or
equal to this threshold, and the value at the last sampling interval is less than this
threshold, a single event is generated.
Falling Threshold
A sampled statistic threshold. When the current sampled value is less than or equal
to this threshold, and the value at the last sampling interval is greater than this
threshold, a single event is generated.
Rising Event
The event index used when a rising threshold is crossed.
Falling Event
The event index used when a falling threshold is crossed.
Owner
The entity that configured this entry.
RMON Commands
525
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents