Routing information source − OSPF and the Static Route table. Routing information will be redistributed to RIP. The following
table lists the allowed values for the routing metrics and the types (or forms) of the routing information that will be redistributed.
Entering the Type combination − internal type_1 type_2 is functionally equivalent to all. Entering the combination type_1
type_2 is functionally equivalent to external. Entering the combination internal external is functionally equivalent to all.
Entering the metric 0 specifies transparency.
Example Usage:
To add route redistribution settings:
DES-6500:4#create route redistribute dst rip src ospf all metric 2
Command: create route redistribute dst rip src ospf all metric 2
Success.
DES-6500:4#
config route redistribute dst ospf src
Purpose
Syntax
Description
Parameters
Route Source
Metric
OSPF
0 to 16
Static
0 to 16
Used configure route redistribution settings for the exchange of RIP
routes to OSPF routes on the Switch.
config route redistribute dst ospf src [static | rip | local]
{mettype [1 | 2] | metric <value 0-16777214>}
Route redistribution allows routers on the network − that are
running different routing protocols to exchange routing information.
This is accomplished by comparing the routes stored in the various
router's routing tables and assigning appropriate metrics. This
information is then exchanged among the various routers according
to the individual routers current routing protocol. The switch can
redistribute routing information between the OSPF and RIP routing
protocols to all routers on the network that are running OSPF or
RIP. Routing information entered into the Static Routing Table on
the local switch is also redistributed.
src [static | rip | local] − Allows the selection of the protocol of the
source device.
mettype − allows the selection of one of the methods for calculating
the metric value.
Type
all
type_1
type_2
inter+e1
inter+e2
external
internal
not applicable