Reflective Sensor Heads: FUN Mode Functions

3-5-11 Display Reverse Function

The display direction of the digital displays can be selected. Select either
forward or backward according to the mounting direction of the Amplifier
Unit.

3-5-12 ECO Display Function

The ECO display function can be enabled or disabled. When the ECO dis-
play function is enabled, the digital display will not light.

3-5-13 Limiting the Number of Display Digits

The number of display digits of the main display and sub-display can be
set. When the number of digits is reduced, the rightmost digit is disabled
first. In addition, if 0 digits are specified, the entire digital display will be dis-
abled. This applies, however, only in RUN Mode.

3-5-14 Setting for Non-measurement

The output method used during non-measurement can be set. This setting
applies when a reset is input or a reception error occurs.
Outputs
Judgement outputs
Linear output
Maximum output voltage: Approximately 5.5 V
Maximum output current: Approximately 23 mA
Refer to 4-5-11 Special FUN Mode Settings Related to Dis-
plays.
All OFF.
Held at the maximum
output value.
Refer to 4-5-12 Other Special FUN Mode Settings.
Setting for non-measurement
CLAMP
The status immediately
before measurement
stopped is held.