Enter/Exit Programming Mode
The features in this section are valid only for the PowerScan PM950X Star
model:
•
•
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the
handheld reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (num-
ber of readers in the same area). The selectable range for this feature is
from 02 to 25 seconds. See
tion and examples for setting this feature.
Set Radio Protocol Timeout
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start
again at the beginning.
DEFAULT
234
PM950X-ONLY FEATURES
STAR Radio Protocol Timeout
STAR Radio Transmit Mode
02 = 2 Seconds Radio Protocol Timeout
page 303
in "References" for detailed informa-
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by two digits from the Alpha-
numeric characters in
resenting your desired character(s). End by
scanning the ENTER/EXIT bar code again.
~
PowerScan™ PD953X/PBT950X/PM950X
Appendix D, Keypad
CANCEL
rep-