Enter/Exit Programming Mode

Append Code

This function defines how a scanned barcode interacts with a pre-edited
CODE field, or with a string entered by a preprogrammed FUNC KEY.
Options are:
0. Barcode data overwrites what is written in the CODE field by keyboard and
1. Barcode data is appended to any text in the CODE field and the code is trans-
2. Barcode data is appended to any text in the CODE field but the code IS NOT
$CPWFW00\r
Overwrite always
$CPWFW02\r
Append and don't transmit

Echo

This function enables/disables the keypad echo. It works only when the
scanner is in simple data input mode (no QTY/CODE).
$CPWKE00\r
Full Keypad echo
$CPWKE02\r
No echo on any key
262
the code is transmitted;
mitted;
transmitted. Data is transmitted when the enter key is pressed.
DEFAULT
$CPWFW01\r
Append and transmit
DEFAULT
$CPWKE01\r
No echo on function key