Motion Features

Motion Features

Motionless Timeout

This setting specifies the amount of time that the reader takes to assume
that it is in a motionless condition. The range for this setting is from 500
msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
3. Go to
4. Scan the bar code: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
This completes the procedure. See
feature.
Table 48. Motionless Timeout Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad
2
with leading zeroes to yield
two digits)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT MOTIONLESS TIMEOUT SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
= 0005 = 00, 5 = 050, 20 = 200, etc.
page 204
and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
pad
representing the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
ming Mode.
EXAMPLES
500ms
005
'0', '0' and '5'
Table 48
for examples of how to set this
1 sec.
10 sec
010
100
'0', '1' and '0'
'1', '0', and '0'
Appendix D, Key-
9,900ms (9.9 sec.)
250
'2', '5', and '0'
301