Erase Batch Memory

When the scanner is configured in Manual Batch Mode, use the following bar
code to erase any labels stored in batch memory.

RF Batch Mode Transmit Delay

Specifies the delay in 10 msec increments between transmitting labels
stored in batch memory.
DEFAULT
$CBTTD05(CR)
RF Batch Mode Transmit Delay = 50 mS
$CBTTD32(CR)
RF Batch Mode Transmit Delay = 0.5 seconds
$CBTTDFA(CR)
RF Batch Mode Transmit Delay = 2.5 seconds
Product Reference Guide
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunc-
tion with this bar code.
BatchClear
Erase Batch Memory
Enter/Exit Programming Mode
$CBTTD00(CR)
RF Batch Mode Transmit Delay = No Delay
$CBTTD0A(CR)
RF Batch Mode Transmit Delay = 100 mS
$CBTTD64(CR)
RF Batch Mode Transmit Delay = 1 second