Incorrect Modification Procedure - IBM 3270 Manual

Information display system; control unit
Hide thumbs Also See for 3270:
Table of Contents

Advertisement

u
Steady Code
Flashing Code
1
Diskette Mounted
Meaning
Action
-
0101
0000
2
System or load
Internal 3274 error or
Check response to sequence
wrong response to sequence
number 113, and retry.
number 113 during
If the error recurs, follow
customizing procedure
your local procedure for
problem recovery.
-
0110
0000
2
System or load
Internal 3274 error or
Check response to sequence
wrong response to sequence
number 111, 112, 151,or
number 111, 112, 151, or
351, and retry. If the error
351 during customizing
recurs, follow your local
procedure
procedure for problem
recovery.
-
0110
0001
3
System or load
Address range set in control
Check responses to sequence
unit does not include
numbers 111, 112, 116, 117,
highest logical device
and 118. If correct have I BM
address assigned during
CE check address range setting
customization
4
in control unit.
-
0111
0000
2
System or load
1.
Internal 3274 error, or
1 and 2. Check responses to
2. Wrong response to
sequence numbers 311
sequence number 311
and 343, and retry.
or 343, or
3. Connect the 3274 to the
3. The 3274 is not con-
communication facility.
nected to the communi-
If the error recurs,
cation facility
follow your local pro-
cedure for problem
recovery.
-
1000
0000
System or load
Internal 3274 error or
Check response to sequence
wrong response to sequence
number 111, and retry.
number 111 during
If the error recurs, follow
customizing procedure
your local procedure for
problem recovery.
-
1001
0000
System or load
Internal 3274 error or
Check response to sequence
wrong response to sequence
number 352, and retry. If
number 352 during
the error recurs, follow your
customizing procedure
local procedure for problem
recovery.
-
1001
1010
System or load
Internal 3274 error or
Check response to sequence
wrong response to
~equence
number 151 and retry. If
number 151 during
the error recurs, follow
customizing
your local procedure for
problem recovery.
-
1001
1110
System or load
Insufficient storage
Follow your local procedure
for problem recovery.
-
1011
0000
System or load
Internal 3274 error or
Check response to sequence
wrong response to sequence
number 127, and retry. If
number 127 during
the error recurs, follow your
customizing procedure
local procedure for problem
recovery.
1101
-
System or load
Uncustomized system
Insert customized system
diskette
diskette.
1110
-
System or load
Insufficient storage
Check response to sequence
number 113,and retry.
If the error recurs, follow
your local procedure for
problem recovery.
1
These codes will flash alternately as shown, for example, 0101, 0000, 0101, 0000, and so on,
2 These codes may blink for 5 seconds, followed by a different steady code for 3 seconds.
3
Models 1D,21 D, and 31 D only. These codes will alternate continuously as follows: left code blinks for 5 seconds,
then right code is on steady for 3 seconds.
4
When the 3290 Information Panel is attached to 32740 units and the Multiple Interactive Screen function is being used,
the address range set in the control unit must include the highest logical device address assigned, not the highest physical
device address.
Note: These indicators may be caused by something other than incorrect customizing. Further aids can be found in
the IBM 3270 Information Display System: 3274 Control Unit Problem Determination Guide. GA27-2850.
Figure 5-7. 8 4 2 1 Indicator Codes during IML That May Result from an
Incorrect Modification
~Procedure
Chapter 5. Modification Procedure
5-17