Step 11. Performing The Checkout Procedure - IBM eserver 7210 Setup And Operator Manual

Hide thumbs Also See for eserver 7210:
Table of Contents

Advertisement

4. __ Review the information in "Indicator Lights" on page 14, then turn on the
power to the 7210 DVD-RAM Drive and watch for the following:
v The status light blinks for about five seconds and goes out, indicating that
the Power-On Self Test (POST) has completed successfully.
v The power-on light comes on and stays on.
5. __ Turn on the power to the system unit.

Step 11. Performing the Checkout Procedure

For RS/6000 or pSeries Systems
To perform the 7210 DVD-RAM Drive checkout procedure, do the following:
1. __ Configure the 7210 DVD-RAM Drive to the host system software by doing
the following:
a. Log into the host system (AIX operating system).
Note: You must have root authority to install or remove the 7210
b. At the system prompt, type
lsdev -Cs scsi
and press Enter. The command lists all of the SCSI devices that are
connected to the host system. Figure 8 shows an example of the screen that
displays. The screen lists:
1
2
3
4
5
Figure 8. Screen Display of SCSI Devices Attached to the host system
DVD-RAM Drive from the system. To obtain root authority, see your
system administrator.
Device name
Device status
SCSI adapter slot number
Description of the SCSI device
SCSI address (begins with 7th digit)
11
Chapter 2. Setting Up