IBM 3270 Manual page 46

Information display system; control unit
Hide thumbs Also See for 3270:
Table of Contents

Advertisement

3274 1
u
1A,
1C,
10,
Sequence
21A,
18,
21C,
210,
Respol'!se
Number
Function
31A
218
31C
51C
310
Notes
Definition
211
SCS support (SDLC only)
x
x
x
-
3
O=No
1-Yes
213
Between bracket printer
x
x
x
-
2
0-No
sharing (SDLC only)
1=Yes
215
Physical unit identification (PU ID)
x
-
x
x
-
2
See Chapter 3.
(SDLC only)
220
Alert Function (SNA only)
x
x
x
5
See Chapter 3.
301
Control unit number ( BSC only)
x
x
-
2
See Chapter 3.
302
SDLC control unit address
x
x
-
2
See Chapter 3.
305
BSC printer polling
x
x
-
6
0-No
1 =Yes
310
Modem connection
-
-
x
x
-
3
See Chapter 3.
311
Modem wrap (external
-
-
x
x
-
3
0-Not possible
modems only)
1 =Possible
313
NRZI (SDLC only)
-
-
x
x
-
3,7
O=NRZ
or NAZ encoding
1=NRZI
313
Internal or external clocking
-
-
x
x
-
6
0-External
(SSC.only)
1=1nternal
314
Multipoint or point-to-point
-
--
x
x
-
3, 7
O=Multipoint
network
1 =Point-to-Point
317
Switched network backup (SNBL)
-
-
x
x
-
3, 7
See Chapter 3.
318
Normal or half-speed transmission
-
-
x
x
-
3, 7
0-Normal
1=Half
321
ASCII or EBCDIC character set
-
-
x
x
-
3, 7
0-EBCDIC
1=ASCll
331
BSC or SDLC protocol
-
-
x
x
-
3, 7
O=BSC
1=SDLC
342
Request-to-send (ATS) control
-
-
x
x
-
3, 7
See Chapter 3.
(2-wire or 4-wire)
343
Communications interface options
-
-
x
x
-
3, 7
See Chapter 3.
345
Answer tone (Configuration
-
--
-
x
-
-
O=Transmit Answer Tone
Support C and T only;
Required
World Trade external
1 =Transmit Answer Tone Not
switched network modems only)
Required
347
High-speed data rate
-
-
-
x
-
-
0-Data rate less than 38.4K
(Configuration Support C and
1 =Data rate 38.4
Loop Attachment only)
351
HPCA (SDLC only)
-
-
x
x
-
3, 7
O=CCA
or CCA adapter
1=HPCA
352
Encrypt/Decrypt (SDLC only)
-
-
x
x
-
3
O=No
(Configuration Support A, B,
1=Yes
and Conly)
360
X.21 Switched retry (Configuration
-
-
-
x
-
-
OO=X.21 Switched not used
Support C and SDLC only)
XX=Number of retries
Minimum 00
361
X .21 Switched retry timing
-
-
-
x
-
-
OO=X.21 Switched not used
(Configuration Support C and
XX=Number of seconds between
SDLC only)
retries, must be from 01 to
20.
362
X.21 Switched option
-
-
-
x
-
-
See Chapter 3.
(Configuration Support
C and SDLC only)
900
Entry acceptance
x
x
x
x
x
1
-
901
Printer authorization matrix
x
x
x
x
x
1
-
acceptance
904
Response Time Monitor
x
x
x
x
x
-
See Appendix K.
Acceptance
999
Specification panel
x
x
x
x
x
1
-
1
An X i.n the model column indicates needed information; a dash indicates not applicable.
Notes:
1.
Information is already identified on the Initial Customizing Procedure Form.
2.
Obtain information from the system programmer.
3.
Obtain information from equipment orders placed with IBM, with the common carrier, and {if necessary) with 'i:he modem manufacturer.
4.
An RPO parameter list is required by certain RPOs. Specific information is supplied with the RPO.
5. Does not apply to Models 18, 21A, 218, 21C, and 21D.
6. Models TC, 21C, 31C, and 51C BSC only.
7.
This parameter must be compatible with the hifst-system communication controller and/or the modem.
Figure 2-1 (Part 2 of 2).
Configuration Information Needed
Chapter 2. Introduction to Customizing
2-5