To replace the component, slide the uFF drive into the bay until it is firmly seated in the adapter and clicks into place.
More information
SFF flash adapter components and LED definitions

Removing and replacing DIMM baffles

Removing the DIMM baffles

The server blade has two DIMM baffles.
Procedure
1. Power down the server blade.
2. Remove the server blade.
3. Place the server blade on a flat, level work surface.
4. Remove the access panel.
5. If installed, remove the internal USB drive.
To locate the internal USB connector, see System board components.
IMPORTANT: When removing a DIMM baffle, do not remove the following options when installed on the DIMM
baffle:
M.2 enablement option (left DIMM baffle)
HPE Smart Storage Battery (right DIMM baffle)
6. If installed, remove the direct connect SATA cable from cable channel on the right air baffle.
7. Remove one or more DIMM baffles:
Removal and replacement procedures