Power down the server blade
Remove the server blade
Removing the access panel
Removing the DIMM baffles

Replacing the M.2 enablement option

Procedure
1. Verify that the PEM nuts and rubber stoppers are in the correct location to support the length of the M.2 SSDs being
installed. If necessary, relocate the PEM nuts and rubber stoppers. For more information, see Relocate the PEM nut
and rubber stopper.
2. Install the M.2 SSD options on the M.2 riser board.
3. Install the M.2 riser board on the left DIMM baffle.
To ensure proper installation, be sure that the M.2 riser board aligns with all alignment guides on the air baffle.
Removal and replacement procedures