6.3.4 NVM IIT

Chain-Link
NVM Name
715-010
Energy Saver Disable
715-018
Config Fail Bypass
715-020
Number Of APS Sensor
715-030
IIT Failure Part Diagnosis
715-050
Platen SS Registration Adjustment
715-051
Platen SS Magnification Adjustment
715-053
Platen PRadjF
715-092
WREF_ADJ__R
715-093
WREF_ADJ__G
715-094
WREF_ADJ__B
Version 1.1
DC SC2020
Table 1 NVM IIT
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
0
1
0
0
1
0
0
1
0
0
65535
0
16
184
100
44
56
50
0
240
120
70
255
140
70
255
140
70
255
140
05/2014
6-35
Read/Write
Description
O
When Setting Value: 0,
At Power OFF: Move the CRG to the W-Ref board position. *Note
At Power ON: Initialize the CRG.
Returning from Energy Saver: Do not initialize the CRG.
When Setting Value: 1,
At Power OFF: Do not move the CRG.
At Power ON: Initialize the CRG.
Returning from Energy Saver: Initialize the CRG.
*Depending on the setting value of 719-999, there might be no movement instead.
For more details, refer to the Meaning column of 719-999.
O
Controls whether to perform Fail bypass for the [Configuration Check] function of IIT-
Elect Request.
Furthermore, this NVM is not involved with the separate SelectConfig that is performed
internally by the IISS.
0: Fail Bypass OFF
1: Fail Bypass ON
O
0: 1 APS
1: 2 APS
O
Writing 1 starts the IIT Faulty Parts Diagnosis.
After that, the write value of this NVM will be changed from '1' to the presumed faulty
Parts No.
After the Faulty Part Diagnosis has completed, reading this NVM displays the pre-
sumed faulty Part No.
When a Fail occurs during the Faulty Part Diagnosis, the Faulty Part Diagnosis ends
after the Fail code is recorded in this NVM.
* If other than '1' has been written, it will follow the usual NVM-Write operation.
(Faulty Parts Diagnosis will not be performed)
O
Regi Correction in Slow Scan Direction
"Factory Settings"
O
Slow Scan Direction Regi Correction Value (0.1% increments)
"Factory Settings"
O
Fast Scan Regi Correction Value (Dot)
VLSS = PROMVLSS + (PRadjF -120) X 2
"Factory Settings"
O
Red W-Ref correction coefficient, "Factory Settings"
O
Green W-Ref correction coefficient, "Factory Settings"
O
Blue W-Ref correction coefficient, "Factory Settings"
6.3.4 NVM IIT