Fuji Xerox DocuCentre SC2020 Service Manual page 571

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

6.3.19 NVM 762_Deve 2 List
Chain-Link NVM Name
762-025
Deve Temperature Raise Band Switch
762-038
#Y Temperature Raise Bank Average A/C
762-039
#M Temperature Raise Band Average A/C
762-040
#C Temperature Raise Band Average A/C
762-041
#K Temperature Raise Band Average A/C
762-042
Y No. of times Temperature Raise Band was cre-
ated
762-043
M No. of times Temperature Raise Band was cre-
ated
762-044
C No. of times Temperature Raise Band was cre-
ated
762-045
K No. of times Temperature Raise Band was cre-
ated
762-046
Temperature Raise Band Width Integrated Value Y 0
762-047
Temperature raise Band Width Integrated Value M
762-048
Temperature Raise Band Width Integrated Value C 0
762-049
Temperature Raise Band Width Integrated Value K 0
762-050
Decay Agitation Execution SW
762-051
Decay Entry Threshold Value
762-052
Decay Temperature Determination Threshold Value 25
762-053
Decay Humidity Determination Threshold Value
762-054
Store SubMot Stop Time (BW)
762-055
Store SubMot Stop Time (FC)
762-056
Decay Setup Length
762-057
DEVE Reverse Rotation SW
762-058
DEVE Reverse Rotation PV Threshold Value
762-059
DEVE Reverse Rotation Time
762-060
Auger Mark Countermeasure SW
Version 1.1
DC SC2020
Table 1 NVM 762_Deve 2 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
1
Temperature Raise Band Execution Selection Switch
0: Do not Execute, 1: Perform
0
0
1000
Average A/C calculated when Temperature Raise Band is decided
0
0
1000
Average A/C calculated when Temperature Raise Band is decided
0
0
1000
Average A/C calculated when Temperature Raise Band is decided
0
0
1000
Average A/C calculated when Temperature Raise Band is decided
0
0
20000
No. of times Temperature Raise Band was created. * Clear with HFSI
reset
0
0
20000
No. of times Temperature Raise Band was created. * Clear with HFSI
reset
0
0
20000
No. of times Temperature Raise Band was created. * Clear with HFSI
reset
0
0
20000
No. of times Temperature Raise Band was created. * Clear with HFSI
reset
0
50000000
Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm]
0
0
50000000
Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm]
0
50000000
Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm]
0
50000000
Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm]
0
0
1
Decay Agitation Execution SW
0: Do not execute Entry Determination, 1: Execute Entry determination
7
0
30
Decay Entry Threshold Value [hour]
(For comparison with the time from the Deve Motor Off to the Entry Deter-
mination)
0
30
Decay Temperature Determination Threshold Value [degrees] (To com-
pare with the temp during Entry)
75
0
100
Decay Humidity Determination Threshold Value [%] (To compare with the
temp during Entry)
0
0
4294967295 Acquires the stop time of Sub Motor during BW Mode.
0
0
4294967295 Acquires the stop time of Sub Motor during FC Mode.
7560
0
30160
Decay Panel Length
0
0
3
DEVE Reverse Rotation Perform SW
0: Do not perform, 1: Execute only in BW, 2: Execute only in FC, 3: Exe-
cute in all Modes
40
0
1000
DEVE Reverse Rotation PV Threshold Value
100
50
200
DEVE Reverse Rotation PV
0
0
1
Performance Switch for Auger Mark Countermeasure
0: Do not perform, 1: Perform
05/2014
6-173
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
0.1[%]
O
O
0.1[%]
O
O
0.1[%]
O
O
0.1[%]
O
O
Times
O
O
Times
O
O
Times
O
O
Times
O
O
O
O
O
O
O
O
O
O
-
O
O
-
O
O
-
O
O
-
O
O
minute
O
O
minute
O
O
mm
O
O
-
O
O
PV
O
O
10[ms]
O
O
-
O
O
6.3.19 NVM 762_Deve 2 List