6.4.17 Parameter (System Data Setting)
You can specify the Fax and Scan system data settings.
6.3.22 System Data List
6.3.3 DADF NVM List
6.3.4 IIT NVM List
Procedure
1.
Enter the CE mode. (See
"6.4.2
How To Enter the CE Mode")
2.
Use the [Down arrow] button to select [Fax/Scanner Diag], and press the [OK] button.
3.
Use the [Down arrow] button to select [Parameter], and press the [OK] button.
Figure 1 j0bs64138
4.
Change the Chain Link number, and press the [OK] button.
Use the [<-] and [->] buttons to move the cursor to right and left.
Use the [Up arrow] and [Down arrow] buttons to increase or decrease the value where the cur-
sor is placed.
Press the [OK] button, and the Chain Link number changed will appear.
05/2014
6-266
5.
Change the setting value, and press the [OK] button.
* (asterisk) will appear when the value is set.
6.
Press the [<--] (Back) button to return to the [Fax Scanner Diag] screen.
7.
Exit the CE mode. (See "6.4.4 How to Exit the CE Mode")
6.4.17 Parameter (System Data Setting)
Figure 2 j0bs64139
Figure 3 j0bs64140
Figure 4 j0bs64141